Ruidong Group Co.,Ltd.
  • 
  • Home
  • Products+
    • Water Cooled Chiller & Heat Pump
      1. Mini Type Water Cooled Scroll Chiller, 7kW-40kW
      2. Water Cooled Scroll Chiller and Heat Pump, 70kW-280kW
      3. Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW
    • Air Cooled Chiller & Heat Pump
      1. Mini Type Air Cooled Scroll Chiller and Heat Pump, 10kW-45kW
      2. Air Cooled Scroll Water Chiller and Heat Pump, 60kW-480kW
      3. Air Cooled Screw Chiller and Heat Pump, 280kW-1120kW
    • Commercial Air Conditioner
      1. Rooftop Package Unit, 18kW-360kW
      2. Ducted Split Unit, 25kW-350kW
      3. Water Cooled Packaged Unit, 30kW-220kW
      4. Mushroom Planting Air Conditioner, 30kW-85kW
      5. Dehumidifier Unit, 25kW-350kW
      6. VRV Air Conditioner
    • Fan Coil Unit
      1. Concealed Fan Coil Unit
      2. Floor / Ceiling Fan Coil Unit
      3. Cassette Fan Coil Unit
    • Air Handling Unit
      1. Combined Type Air Handling Unit
      2. Ceiling Type Air Handling Unit
      3. Horizontal Type Air Handling Unit
      4. Vertical Type Air Handling Unit
      5. Fresh Air Ventilation Unit
    • Ventilation Fan & Fan Box
      1. Ventilation Fan
      2. Centrifugal Fan Box
    • Fire Damper
    • Air Conditioning System Components
    • Cooling Tower
  • About+
    • Company
    • Certificates
    • Team Staff
    • Factory Pictures
    • Service
  • Projects+
    • Rooftop Unit in Leroy Merlin
    • Mushroom greenhouse project in Seoul, Korea
    • Water Chiller and Cooling Tower in Red Star Macalline, Binzhou, China
    • Water Cooling Unit in Tangshan Vocational Technical College
    • HVAC Projects in China Textile and Apparel Center
    • Air Conditioning Projects in Institute of Botany, the Chinese Academy of Sciences
    • Air Cooled Chiller and Water Cooled Chiller in Beijing Nongcube Greenhouse, Beijing, China
  • Videos
  • News
  • Contact
  • Home
  • Products
  • Water Cooled Chiller & Heat Pump
  • Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW

Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW

Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW
  • Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW
  • Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW
  • Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW
  • Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW
  • Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW
  • The water source and ground source heat pump is designed and produced by Ruidong for heating, cooling, and heat recovery in large commercial applications. These pumps are suitable for installation in malls, office buildings, workshops, hotels, hospitals and other large-scale structures.

    Request a Quote
    Video
    Download

    Water Cooled Screw Chiller

    • Specifications 1
    • Specifications 2
    • Specifications 3
    • Catalogue

    Screw Type High Temperature Hot Water Chiller

    • Specifications 1
    • Catalogue

    Screw Type Low Temperature Water Cooled Chiller

    • Specifications 1
    • Specifications 2
    • Specifications 3
    • Specifications 4
    • Catalogue

    Screw Type Water Source Heat Pump

    • Specifications 1
    • Specifications 2
    • Specifications 3
    • Catalogue
    Technical Parameters

    Unit model- RLSG
    200A
    240A
    260A
    300A
    330A
    360A
    400A
    440A
    Nominal cooling capacity kW 204 236 256 295 329 364 389 441
    Input power kW 40 46 49.7 55.5 62.7 67.8 73.1 81.5
    Running current A 74.3 85.1 90.4 98.8 112.7 124.8 132.0 146.4
    Max. running current A 99.3 114.0 122.0 134.1 151.8 165.5 177.3 197.3
    Cable diameter (copper wire distance ≤ 20 meters) mm2 3*35+2*16 3*35+2*16 3*50*2*25 3*50+2*25 3*70+2*35 3*70+2*35 3*95+2*50 3*120+2*50
    Power voltage 3-380V-50Hz
    Starting mode Y-▲
    Refrigerant R134a
    Refrigerant charge 41 47 51 57 66 71 78 86
    Refrigerant control device Electronic expansion valve(EXV)
    Compressor Type Semi-hermetic screw
    Qty 1
    Evaporator Type Shell& tube type
    Water pressure drop kPa 70-90
    Water pipe Dia. DN 100 100 100 100 100 100 100 100
    Water flow m3/h 35 41 44 51 57 63 67 76
    Condenser type Type Shell& tube type
    Water pressure drop kPa 70-90
    Water pipe Dia. DN 100 100 100 100 100 100 100 100
    Water flow m3/h 41 51 55 63 71 78 84 95
    Noise level dB(A) 79.6 80.4 81.5 83.1 84.2 85.2 86.3 86.9
    Unit structure Horizontal type
    Dimensions(mm) L 3000 3000 3000 3000 3000 3000 3000 3000
    W 1350 1350 1350 1350 1450 1450 1450 1450
    H 1600 1600 1650 1650 1650 1800 1800 1800
    Installation dimensions(mm) L1 2230 2230 2230 2230 2230 2230 2230 2230
    W1 790 790 790 790 880 880 880 880
    Net weight kg 1700 1800 1850 1950 1950 2100 2250 2450
    Running weight kg 2200 2400 2550 2750 2850 3100 3350 3750
    Remarks Cooling conditions Chilled water inlet/outlet temperature 12℃/7℃; cooling water inlet/outlet temperature 30℃/35℃;

    Unit model - RLSG
    500A
    580A
    600A
    700A
    800A
    900A
    1000A
    Nominal cooling capacity kW 505 574 596 700 813 888 1020
    Input power kW 93.4 102.1 110.9 126.3 146.3 159.4 181.5
    Running current A 171.2 186.1 201.9 229.4 272.7 291,2 330.1
    Max. running current A 225.7 246.1 267.1 304 364 393.2 443
    Cable diameter (copper wire distance ≤ 20 meters) mm2 3*120+2*50 3*150+2*70 3*150+2*70 3*185+2*95 3*185+2*95 3*240+2*120 3*240+2*120
    Power voltage 3-380V-50Hz
    Starting mode Y-▲
    Refrigerant R134a
    Refrigerant charge 100 109 119 136 160 178 203
    Refrigerant control device Electronic expansion valve(EXV)
    Compressor Type Semi-hermetic screw
    Qty 1
    Evaporator Type Shell& tube type
    Water pressure drop kPa 70-90
    Water pipe Dia. DN 125 125 125 150 150 150 150
    Water flow m3/h 87 99 103 120 140 153 175
    Condenser type Type Shell& tube type
    Water pressure drop kPa 70-90
    Water pipe Dia. DN 125 125 125 150 150 150 150
    Water flow m3/h 109 123 128 151 175 191 219
    Noise level dB(A) 87.1 87.3 87.6 88.4 90.1 90.5 90.8
    Unit structure Horizontal type
    Dimensions(mm) L 3400 3400 3500 3500 3500 3500 3500
    W 1450 1600 1600 1600 1600 1600 1600
    H 1800 1800 1850 1850 1850 1950 1950
    Installation dimensions(mm) L1 2735 2735 2735 2735 2735 2735 2735
    W1 880 1300 1300 1300 1300 1300 1300
    Net weight kg 2650 2850 3100 3300 3500 3700 4300
    Running weight kg 4050 4350 4450 4700 5000 5400 6000
    Remarks Cooling conditions Chilled water inlet/outlet temperature 12℃/7℃; cooling water inlet/outlet temperature 30℃/35℃;

    Unit model -RLSG
    400A
    480A
    520A
    600A
    660A
    720A
    800A
    880A
    Nominal cooling capacity kW 408 472 512 590 658 728 778 882
    Input power kW 80 92 99.4 111 125.4 135.6 146.2 163
    Running current A 148.6 170.2 180.8 197.6 225.4 249.6 264 292.8
    Max. running current A 198.6 228.0 244.0 268.2 303.6 331.0 354.6 394.6
    Power voltage 3-380V-50Hz
    Starting mode Y-▲
    Refrigerant R134a
    Refrigerant charge 82 94 102 114 132 142 156 173
    Refrigerant control device Electronic expansion valve(EXV)
    Compressor Type Semi-hermetic screw
    Qty 2
    Evaporator Type Shell & tube type
    Water pressure drop kPa 70-90
    Water pipe Dia. DN 100 125 125 125 150 150 150 150
    Water flow m3/h 70 81 88 101 113 125 134 152
    Condenser type Type Shell & tube type
    Water pressure drop kPa 70-90
    Water pipe Dia. DN 100 125 125 125 150 150 150 150
    Water flow m3/h 88 101 110 127 141 157 167 190
    Noise level dB(A) 79.6 80.4 81.5 83.1 84.2 85.2 86.3 86.9
    Unit structure Horizontal type
    Dimensions(mm) L 3650 3750 4400 4400 4500 4500 4500 4500
    W 1500 1500 1500 1500 1700 1700 1700 1700
    H 1800 1900 1900 1900 2050 2050 2050 2050
    Installation dimensions(mm) L1 2735 2735 2735 2735 2735 3435 3435 3435
    W1 1140 1140 1140 1140 1350 1350 1350 1350
    Net weight kg 3100 3750 4000 4200 4400 4800 5000 5500
    Running weight kg 4350 5050 5400 5700 5900 6300 6700 7300
    Remarks Cooling conditions Chilled water inlet/outlet temperature 12℃/7℃; cooling water inlet/outlet temperature 30℃/35℃;

    Unit model -RLSG
    1000A
    1160A
    1200A
    1400A
    1600A
    1800A
    2000A
    Nominal cooling capacity kW 1010 1148 1192 1400 1626 1776 2040
    Input power kW 186.8 204.2 221.8 252.6 292.6 318.8 363
    Running current A 342.4 372.2 403.8 458.8 545.4 582.4 660.2
    Max. running current A 451.4 492.2 534.2 608.0 728.0 786.4 886.0
    Power voltage 3-380V-50Hz
    Starting mode Y-▲
    Refrigerant R134a
    Refrigerant charge 200 218 238 273 319 355 406
    Refrigerant control device Electronic expansion valve(EXV)
    Compressor Type Semi-hermetic screw
    Qty 2
    Evaporator Type Shell & tube type
    Water pressure drop kPa 70-90
    Water pipe Dia. DN 150 150 200 200 200 200 250
    Water flow m3/h 174 197 205 241 280 305 351
    Condenser type Type Shell & tube type
    Water pressure drop kPa 70-90
    Water pipe Dia. DN 150 150 200 200 200 200 250
    Water flow m3/h 217 247 256 301 350 382 439
    Noise level dB(A) 87.1 87.3 87.6 88.4 90.1 90.5 90.8
    Unit structure Horizontal type
    Dimensions (mm) L 4500 4750 4750 4750 4750 4750 4750
    W 1700 1900 1900 1900 1900 1900 1900
    H 2050 2000 2000 2000 2000 2000 2000
    Installation dimensions (mm) L1 3435 3435 3435 3435 3435 3435 3435
    W1 1350 1350 1350 1350 1350 1350 1350
    Net weight kg 5900 6200 6600 7000 7400 8000 8700
    Running weight kg 7600 7900 8400 8800 9200 9800 10700
    Remarks Cooling conditions Chilled water inlet/outlet temperature 12℃/7℃; cooling water inlet/outlet temperature 30℃/35℃;
    Protection measures
    • High and low voltage protection
    • Anti-freezing protection
    • Temperature control
    • Power anti-phase protection
    • High & low pressure protection
    • High pressure exhaust temperature protection
    • Built-in motor overheating protection
    • Over-current protection
    • Safety valve
    • Check valve
    Features
    • Compressor a. Semi-closed dual screw design. Compressed parts are composed of two intermeshing rotors, designed to minimize vibration. The screw design leads to high efficiency and smooth air flow through the process of intake, compression and exhaust.
      b. The equipment does not need to be manually lubricated.
      c. The compressor's volume control system can easily perform partial load operation. The compressor can achieve 25%-100% sectional adjustment or non-sectional energy adjustment to be fully compatible with building loads.
      Advantages
      Moving components are only 1/4 of that of piston compressors. Vulnerable parts are minimized and the inhale and exhaust processes are smooth and continuous without pulse phenomenon. The equipment is not sensitive to wet compression and is highly resistant to strong liquid impact.
    • Shell and tube type heat exchanger Shell: pressure vessels are constructed form high-quality steel plate. Its manufacture and testing meets JB/T4750-2003 ‘Pressure Vessel for Refrigeration Equipment' standards. Exterior surface features flame-retardant water-proof heat-insulation and preservation materials. The evaporator baffle plate adopts PVC engineering plastic which has excellent corrosion resistance and good air impermeability to make the cooling water flow upwards and downwards along the baffle plate. This improves the heat exchange capacity of the evaporator.
      The refrigerant inlet is equipped with a flow-equalizing device in order to uniformly distribute the refrigerant in the heat exchanger's copper tube. This improves the heat exchange efficiency of the whole unit.
      The DAC corrugated inner grooved heat exchange tube is made from copper, improving its efficiency. The power side heat exchange capacity for refrigerant improves the cooling and heating effects of the unit.
    • Expansion valve The electronic expansion valve control system can reach a control accuracy up to 2600 steps. According to suction superheating and saturation pressure, combined with the electronic control system, we can precisely control the refrigerant flow, so as to ensure the unit is always in best running condition and the maximum capacity can be achieved. The adoption of highly efficient heat exchange tubes improves energy efficiency and effectiveness.
    • Distribution control cabinet The distribution control cabinet is composed of compressor starting equipment, a power protector and a micro-computerized controller. The micro-computerized controller can run stably and safely under a temperature range of -15℃ to 65℃. It is equipped with a RS-232 and RS-485 standard communication interface. It can receive a remote signal for starting up and shutting down.
    • Safety equipment High and low voltage switch, anti-freezing temperature control, lube oil heater, high-pressure exhaust check valve, replaceable filter element dry filter, piezometer, emergency stop switch, overload protector, power protector, refrigerant injector.
    Related Products
    • Mini Type Water Cooled Scroll Chiller, 7kW-40kW
    • Water Cooled Scroll Chiller and Heat Pump, 70kW-280kW
    • Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW
    Get in Touch
    • Water Cooled Chiller & Heat Pump
      1. Mini Type Water Cooled Scroll Chiller, 7kW-40kW
      2. Water Cooled Scroll Chiller and Heat Pump, 70kW-280kW
      3. Water Cooled Screw Chiller and Heat Pump, 200kW-2400kW
    • Air Cooled Chiller & Heat Pump
      1. Mini Type Air Cooled Scroll Chiller and Heat Pump, 10kW-45kW
      2. Air Cooled Scroll Water Chiller and Heat Pump, 60kW-480kW
      3. Air Cooled Screw Chiller and Heat Pump, 280kW-1120kW
    • Commercial Air Conditioner
      1. Rooftop Package Unit, 18kW-360kW
      2. Ducted Split Unit, 25kW-350kW
      3. Water Cooled Packaged Unit, 30kW-220kW
      4. Mushroom Planting Air Conditioner, 30kW-85kW
      5. Dehumidifier Unit, 25kW-350kW
      6. VRV Air Conditioner
    • Fan Coil Unit
      1. Concealed Fan Coil Unit
      2. Floor / Ceiling Fan Coil Unit
      3. Cassette Fan Coil Unit
    • Air Handling Unit
      1. Combined Type Air Handling Unit
      2. Ceiling Type Air Handling Unit
      3. Horizontal Type Air Handling Unit
      4. Vertical Type Air Handling Unit
      5. Fresh Air Ventilation Unit
    • Ventilation Fan & Fan Box
      1. Ventilation Fan
      2. Centrifugal Fan Box
    • Fire Damper
    • Air Conditioning System Components
    • Cooling Tower
    Other Products
      1. Cooling Tower
      2. Cooling Tower
      1. Horizontal Type Air Handling Unit
      2. Horizontal Type Air Handling Unit
      1. Industrial Axial Flow Fan
      2. Industrial Axial Flow Fan
      1. Cassette Fan Coil Unit
      2. Cassette Fan Coil Unit
    Products
    • Water Cooled Chiller & Heat Pump
    • Air Cooled Chiller & Heat Pump
    • Commercial Air Conditioner
    • Fan Coil Unit
    • Air Handling Unit
    • Ventilation Fan & Fan Box
    • Fire Damper
    • Air Conditioning System Components
    • Cooling Tower
    Quick Links
    • Projects
    • Company
    • Certificates
    • Team Staff
    • Factory Pictures
    • Service
    • Review
    Contant Us
    No.6555, Tianqu East Road, East Economic Development Zone, Dezhou City, Shandong Province, P.R.China
    Lory Luo
    retw@ruidonggroup.com
    +86-15505345921
    Supported by ETW International Inc. USA