Ceiling Type Air Handling Unit

Application

Ceiling mounted air cooling units are used for ventilation and refrigeration in a number of buildings, ranging from industrial factories to shopping malls.

Technical Parameters
Parameters of FPD series heating units (Z type and J type)
Model Blast capacity Return air working condition Fresh air working condition
1 row of heating tube 2 rows of heating pipe Diameter of tube 1 row of heating pipe 2 rows of heating pipe Water pipe diameter
Nominal heating capacity Water flow Water resistance Nominal heating capacity Water flow Water resistance Nominal heating capacity Water flow Water resistance Nominal heating capacity Water flow Water resistance
FPD m3/h KW m3/h kPa KW m3/h kPa DN KW m3/h kPa KW m3/h kPa DN
010 1000 3.0 0.52 0.2 6.3 1.08 1.0 40 4.5 0.77 0.6 7.6 1.31 0.8 40
015 1500 4.4 0.76 0.2 10.2 1.75 2.2 40 6.1 1.05 0.7 11.9 2.05 2.3 40
020 2000 6.8 1.17 0.6 14.4 2.48 2.9 40 9.2 1.58 1.2 17.5 3.01 4.2 40
025 2500 8.5 1.46 0.8 17.8 3.06 3.1 40 11.3 1.94 1.2 22.1 3.80 4.7 40
030 3000 11.1 1.91 1.3 21.1 3.63 5.2 40 14.2 2.44 2.1 26.8 4.61 8.8 40
040 4000 15.1 2.60 1.4 28.0 4.82 6.8 40 19.1 3.29 2.3 34.7 5.97 10.1 40
050 5000 19.5 3.35 2.4 36.5 6.28 12.0 40 25.3 4.35 5.1 43.2 7.43 15.2 40
060 6000 23.3 4.01 3.1 42.0 7.22 14.9 40 31.1 5.35 5.1 51.8 8.91 18.8 40
070 7000 28.2 4.85 4.2 48.8 8.39 18.2 40 34.2 5.88 6.2 62.2 10.70 28.2 40
080 8000 32.1 5.52 3.8 56.7 9.75 18.6 40 41.1 7.07 7.4 71.4 12.28 26.1 40
090 9000 37.7 6.48 5.2 65.4 11.25 25.6 40 46.2 7.95 9.5 79.3 13.64 32.8 40
105 10500 44.2 7.60 8.5 78.1 13.43 33.4 40 53.3 9.17 12.8 95.2 16.37 42.3 40
120 12000 51.3 8.82 9.8 89.6 15.41 37.2 40 61.1 10.51 14.1 110.1 18.94 49.2 40
135 13500 57.2 9.84 9.8 99.7 17.15 38.2 40 68.2 11.73 15.4 121.5 20.90 49.6 40
150 15000 62.8 10.80 10.1 109.2 18.78 39.6 40 73.9 12.71 17.2 131.4 22.60 51.4 40
FPD/T Type with 1 row of heating pipe (High static pressure type)
Model Air flow Return air working condition Fresh air working condition
Nominal heating capacity Water flow Water resistance Static pressure Nominal heating capacity Water flow Water resistance Static pressure
FPD/T m3/h KW m3/h kPa Pa KW m3/h kPa Pa
010 H 1000 3.7 0.6 0.31 50 5.3 0.9 1.2 110
M 850 3.6 32 5.2 80
L 580 3.2 26 4.9 60
015 H 1500 4.6 0.8 0.54 50 6.5 1.1 2.0 110
M 1300 4.3 32 5.9 80
L 860 3.7 26 5.1 60
020 H 2000 7.9 1.4 0.84 50 10.1 1.7 3.2 110
M 1800 7.3 32 9.2 80
L 1200 6.4 26 7.9 60
025 H 2500 8.6 1.5 1.2 100 11.1 1.9 4.3 160
M 2200 7.9 73 10.4 120
L 1520 6.7 56 9.2 90
030 H 3000 11.3 1.9 2 100 14.2 2.4 7.1 160
M 2600 10.4 73 13.1 120
L 1800 9.2 56 11.2 90
040 H 4000 14.8 2.5 3.4 70 17.9 3.1 10.7 130
M 3500 12.9 55 16.4 100
L 2400 11.6 40 4.3 70
050 H 5000 19.1 3.3 6.5 70 23.6 4.1 20.6 130
M 4300 17.5 55 21.7 100
L 3000 14.6 40 18.1 70
060 H 6000 22.4 3.9 7.3 70 27.6 4.7 20.9 190
M 5000 20.9 55 25.4 145
L 3500 17.4 40 21.3 110
070 H 7000 26.7 4.6 8.6 165 32.8 5.6 21.5 230
M 6000 24.1 180 29.4 180
L 4200 20.1 135 24.3 135

Notes:
Cooling working conditions- The air inflow dry bulb temperature is 27℃ and wet bulb is 19.57℃. Inflow and outflow water temperature is 7℃/12℃.
Heating working conditions- The air inflow dry bulb temperature is 15℃, hot water inflow temperature is 60℃. The water flow of heating conditions is the same as that of cooling conditions.

FPD/T type with 1 row of heating pipe (Normal static pressure type)
Model Air flow Return air working condition Fresh air working condition
Nominal heating capacity Water flow Water resistance Static pressure Nominal heating capacity Water flow Water resistance Static pressure
FPD/T m3/h KW m3/h kPa Pa KW m3/h kPa Pa
010 H 1000 3.7 0.6 0.31 50 5.3 0.9 1.2 50
M 850 3.6 32 5.2 32
L 580 3.2 26 4.9 26
015 H 1500 4.6 0.8 0.54 50 6.5 1.1 2.0 50
M 1300 4.3 32 5.9 32
L 860 3.7 26 5.1 26
020 H 2000 7.9 1.4 0.84 50 10.1 1.7 3.2 50
M 1800 7.3 32 9.2 32
L 1200 6.4 26 7.9 26
025 H 2500 8.6 1.5 1.2 100 11.1 1.9 4.3 100
M 2200 7.9 73 10.4 73
L 1520 6.7 56 9.2 56
030 H 3000 11.3 1.9 2 100 14.2 2.4 7.1 100
M 2600 10.4 73 13.1 73
L 1800 9.2 56 11.2 56
040 H 4000 14.8 2.5 3.4 70 17.9 3.1 10.7 70
M 3500 12.9 55 16.4 55
L 2400 11.6 40 4.3 40
050 H 5000 19.1 3.3 6.5 70 23.6 4.1 20.6 70
M 4300 17.5 55 21.7 55
L 3000 14.6 40 18.1 40
060 H 6000 22.4 3.9 7.3 70 27.6 4.7 20.9 70
M 5000 20.9 55 25.4 55
L 3500 17.4 40 21.3 40
070 H 7000 26.7 4.6 8.6 165 32.8 5.6 21.5 165
M 6000 24.8 125 30.1 125
L 4200 20.7 110 25.4 110

Notes:
Fresh air working conditions: The air inflow dry bulb temperature is 7℃. Hot water inflow temperature is 60℃.
Return air dry bulb temperature is 15℃. Hot water inflow temperature is 60℃.

Product feature

1. Use of an aluminum alloy frame ensures a light weight, making it convenient for onsite dismounting and maintenance.
2. Internal and external double layer polyurethane color steel panels avoids the formation of a cold bridge on the shell while operating.
3. Units are operated and tested using dynamic and static equilibrium tests before delivery.
4. Closed rolling bearings are used for the automatic adjusting center of gravity, automatic locking and push resistance. Pre-filling the lube oil ensures maintenance is not necessary during normal operating conditions.
5. The filter is a plate type that can be cleaned and reused.